The device has two independent counting inputs that can operate in various configurations. A programmable function input enables changing the operating mode of the counting inputs (up-down and down-up) or stopping the count. The SLIK-73 counter features an independent reset input. It has 0 or 1 relay (or OC) output with programmable activation threshold, which can be used to control external equipment.
Parameters
Power supply | 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC |
---|---|
Measurement range | -99999 ÷ 999999 |
Power consumption | for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W |
Inputs | pulse, 2 x counting; 1 x programmable, 1 x reset |
Counting mode | adding, subtracting or quadrature |
Data memory | non-volatile memory, EEPROM type |
Input levels | low: 0 V ÷ 1 V; high: 10 V ÷ 30 V |
Input frequency | electronic: 10 kHz / 5 kHz (for quadrature); contact: max. 90 Hz (adjustable filter) |
Communication interface | RS-485, 1200 ÷ 115200 bit/s, 8N1 and 8N2, Modbus RTU |
Output | 0 or 1; relay 1A/250V AC (cosφ=1) or OC 30mA/30VDC/100mW; power supply output: 24V DC +5%, -10% / max. 100 mA |
Storage temperature | -10°C ÷ +70°C or -20°C ÷ +70°C (with option 08) |
Operating temperature | 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) |
Reset | reset: button and electric, with keylock |
Case | panel mounting |
Case material | NORYL-GFN2S E1 |
Case dimensions | 72 x 36 x 97 mm |
Protection class | IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) |
Panel cut-out dimensions | 66,5 x 32,5 mm |
Display | LED, red, 6 x 9 mm high |
Installation depth | min 102 mm |
Typical applications | Counting current amount of manufactured items plus control of the production line |