TRS-04a
The temperature and humidity transducer is designed for multipoint temperature and humidity measurement systems. In particular it is used for measuring conditions in rooms where food products are manufactured and stored.
Parameters
Power supply | typ. 10V DC (9V DC ÷ 12V DC) |
---|---|
Power consumption | during Modbus transmission: do 60 mA |
Input | temp. sensor: semiconductor integrated circuit; measurement range -40°C ÷ +70°C; measurement error ±0,5°C; humidity sensor: 0 ÷ 100% RH, accuracy ±2% RH @25°C |
Communication interface | RS-485 / Modbus RTU |
Storage temperature | -40°C ÷ +85°C |
Operating temperature | -40°C ÷ +70°C (non-condensing) |
Case dimensions | 63 x 58 x 35 mm |
Protection class | IP 65 (case), IP 30 (sensor) |
Mounting | to wall, 2 M3 bolts |
Transmission parameters | 9600 bit/sek. |
Connection cable | 4 conductors (2 supply conductors + 2 data transmission conductors) |
Number of modules in 1 network | max. 127 |
Remarks | Do not exceed the temperature range of 0 – 70°C. The module should not be used where water vapour condensation occurs. |