SLIK-94
The device has two independent counting inputs that can operate in various configurations. A programmable function input enables changing the operating mode of the counting inputs (up-down and down-up or quadrature) or stopping the count. The SLIK-94 counter features an independent reset input. It has 0, 2 or 4 relay (or OC) outputs with programmable activation thresholds, which can be used to control external equipment.
Parameters
Power supply | 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC |
---|---|
Measurement range | -99999 ÷ 999999 |
Power consumption | for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W |
Inputs | pulse, 2 x counting; 1 x programmable, 1 x reset |
Counting mode | adding, subtracting or quadrature |
Data memory | non-volatile memory, EEPROM type |
Input levels | low: 0 V ÷ 1 V; high: 10 V ÷ 30 V |
Input frequency | electronic: 10 kHz / 5 kHz (for quadrature); contact: max. 90 Hz (adjustable filter) |
Communication interface | RS-485, 1200 ÷ 115200 bit/s, 8N1 and 8N2, Modbus RTU |
Output | 0, 2 or 4; relay 1A/250V AC (cosφ=1) or OC 30mA/30VDC/100mW; power supply output: 24V DC +5%, -10% / max. 100 mA |
Storage temperature | -10°C ÷ +70°C or -20°C ÷ +70°C (depending on version) |
Operating temperature | 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) |
Reset | reset: button and electric, with keylock |
Case | panel mounting |
Case material | NORYL-GFN2S E1 |
Case dimensions | 96 x 48 x 100 mm |
Protection class | IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) |
Panel cut-out dimensions | 90,5 x 43 mm |
Display | LED, red (green on request), 6 x 13 mm high |
Installation depth | min 102 mm |
Typical applications | Measuring the length of the material being wound, featuring control of the cutting knife drive system according to set parameters, control of the material drive system, as well as alarm signalling. |